The cream-labelled foam fire extinguisher is one of the most widely used types in UK workplaces. It tackles both Class A (solid combustibles) and Class B (flammable liquids), making it a sensible single-unit choice for premises that carry a mix of paper, furniture, fuel, paint and solvents. Selection depends on the fire risk assessment and the rating of the particular unit.
In 2025-26, foam is also the type going through the most regulatory change in a generation. The “forever chemical” PFOA was banned in UK firefighting foams from 5 July 2025, and a wider Great Britain restriction on PFAS foams is being considered following consultation. This page covers what foam extinguishers do, how they work, and exactly where the regulatory line currently sits — because most older guides on the topic are now out of date.
What a foam fire extinguisher is
A foam extinguisher is a stored-pressure unit containing a foam concentrate dissolved in water. When discharged, the agent expands as it leaves the nozzle, producing a layer of foam that smothers the fire and cools the fuel surface.
The body is signal red, with a cream-coloured panel near the label that identifies the type — the cream panel is the visual cue everyone learns. The unit is rated under BS EN 3 (the European product standard) and selected and positioned in UK premises under BS 5306-8:2023.
Foam extinguishers come in two main capacities — 6 L and 9 L — with typical fire ratings around 13A 113B for a 6 L unit and 21A 183B for a 9 L unit. Some are also dielectrically tested for use on live electrical equipment, normally up to 1000 V at 1 metre — that rating must be on the label of the specific unit; it cannot be assumed.
How foam extinguishers work
Foam extinguishers attack the fire on two fronts. The foam layer forms a continuous blanket over the burning fuel — particularly important for flammable liquids — that physically separates the fuel from the air. With no oxygen reaching the surface, the fire suffocates. At the same time, the water content of the foam cools the fuel and the surrounding material, lowering the temperature below the ignition point.
For a Class B fire (a tray of burning solvent, a small fuel spill), the foam blanket is the critical mechanism. Once a continuous layer is established, the fire is starved of oxygen and the vapours trapped under the foam can no longer feed the flames. Break the blanket — for example, by walking through it — and the fire can re-ignite. That is why the standard technique for foam on a flammable-liquid fire is to sweep gently across the surface and build a continuous layer, rather than blasting straight at the fuel.
For a Class A fire (paper, wood, fabric), the foam works more like water with a longer residence time. The water content cools, the foam clings to vertical surfaces, and the agent penetrates burning fabric and upholstery more readily than plain water.
What foam extinguishers tackle
Class A and Class B. The standard examples:
- Class A: paper, cardboard, wood, fabric, soft plastics, coal — the same combustibles a water extinguisher handles, with the foam giving better coverage on vertical surfaces and through upholstery.
- Class B: petrol, diesel, paraffin, kerosene, oil-based paints, solvents — small to medium liquid fires, particularly contained ones (a tray, a spill, a small fuel store).
That coverage makes foam a very practical workplace primary — a single foam extinguisher addresses both the dominant Class A risk in a typical office and the smaller Class B risks (cleaners, paint, small fuel tins) that often sit alongside it.
What foam doesn’t tackle:
- Class C (flammable gases) — foam does nothing useful.
- Class F (cooking oils and fats) — foam can splash burning oil, much like water; wet chemical is the right answer.
- Class D (combustible metals) — foam reacts with hot reactive metals.
- Live electrical equipment — only with a current dielectric rating on the label, and even then with the stated voltage and distance limits respected.
The PFAS picture in 2025-26
Different restrictions apply to particular persistent organic pollutants and to proposals covering the wider PFAS family.
Many older foam extinguishers contain AFFF — Aqueous Film-Forming Foam — which historically used a class of synthetic chemicals called PFAS (per- and poly-fluoroalkyl substances), or “forever chemicals,” to lower the foam’s surface tension and improve performance on flammable liquids. The two specific PFAS chemicals that have been at the centre of UK regulatory attention are PFOS and PFOA.
PFOS has been banned in UK firefighting foams for over a decade. Most foam extinguishers manufactured since around 2011 are PFOS-free.
The exemption for specified PFOA firefighting-foam uses ended on 4 July 2025; use of affected foams and contaminated systems has been prohibited since 5 July. This is under the UK persistent organic pollutants (POPs) regime, not the separate UK REACH proposal for wider PFAS restrictions.
“C6” is not a guarantee of legal compliance: the formulation and any regulated contaminants matter. HSE’s consultation on a wider Great Britain PFAS restriction closed on 18 February 2026. A proposal or consultation does not itself create a new ban or a confirmed replacement deadline.
EU and Great Britain restriction processes have separate rules and transition periods. Northern Ireland may be subject to relevant EU requirements; check the rules applying where equipment is supplied or used.
Does my foam extinguisher contain PFOA?
The practical question for most readers. A few ways to work it out:
Check the manufacture date
A manufacture date alone cannot establish the foam’s composition or compliance. Obtain the manufacturer’s identification of the agent and supporting documentation, particularly for older or refilled units.
Check the label
The Safety Data Sheet for the foam should specify the chemistry. Older units may list “AFFF” without further detail; newer compliant units typically state “C6,” “fluorotelomer,” “PFOA-free,” or “fluorine-free.”
Ask the manufacturer or supplier
For ambiguous cases, the manufacturer or your servicing contractor can confirm the chemistry. A BAFE SP101-registered servicing organisation will be able to identify and document the agent.
Don’t assume refilling fixes the problem
Simply replacing the liquid does not prove compliance. Residual contamination and the manufacturer’s approved agent and fire rating must be assessed; any decontamination or conversion needs a documented, competent process.
If you have foam extinguishers that contain PFOA, they must be removed from service and disposed of via a licensed hazardous waste contractor. PFOA-containing foams require high-temperature incineration; they cannot be put into general waste or discharged to drain. The disposal route is on our fire extinguisher disposal page.
Fluorine-free foam — the long-term answer
Fluorine-free foam, often called F3 or FFF, avoids intentionally added fluorinated surfactants. Its formulation, fire rating and compatibility vary by product; a replacement must provide suitable protection for the assessed fuels, including any water-miscible solvents.
Two practical considerations. First, fluorine-free foams may have different application rates and discharge patterns than legacy AFFF — when transitioning, check the new unit’s rating against the fire risks identified in your fire risk assessment. Second, manufacturers’ “PFAS-free” or “fluorine-free” claims should be checked against the product’s Safety Data Sheet to confirm what the unit actually contains.
Fluorine-free products are available, but a planned changeover should check performance, compatibility and waste arrangements. Existing units can remain only where their formulation, condition and use comply with the applicable rules; a C6 label is not enough by itself.
Use on electrical equipment — only with the rating
Some foam extinguishers are dielectrically tested and carry a marking authorising use on live electrical equipment, normally up to 1000 V at a minimum distance of 1 metre. Where a foam extinguisher carries that marking, it can be used on an electrical fire within the stated limits.
Without that marking, foam should be assumed unsafe on live electrical equipment. Standard foam contains enough water to conduct, and the conductivity worsens once the foam contacts heated and partially-combusted material. If electrical fire cover is a primary requirement for your premises, a CO2 fire extinguisher or a dielectrically-tested water mist unit are simpler and safer choices than foam. The detail is on our guide on the right extinguisher for electrical fires.
Where foam extinguishers belong
Typical UK placements:
Offices, retail, hotels
A 6 L foam extinguisher per fire point covers Class A (paper, furniture) and small Class B (cleaning solvents, alcohol-based hand sanitisers), often paired with a CO2 unit for electrical risk.
Workshops, light industrial
A 9 L foam extinguisher near workbenches, fuel storage, or paint stores covers both the Class A debris fires and the small Class B liquid risks. Larger workshops add ABC dry powder for outdoor or specialist coverage.
Hotel kitchens (back-of-house)
Foam covers the Class A risk in storage and prep areas. The cooking line itself needs a wet chemical extinguisher and a fire blanket — foam is not a kitchen-line answer.
Garages and forecourts
Foam is appropriate inside the building (offices, parts stores). Outdoors near pumps, dry powder is usually preferred for the higher Class B exposure.
UK capacities are normally 6 L and 9 L for hand-held units. Larger wheeled foam extinguishers exist for industrial sites and aviation contexts.
Servicing
Foam extinguishers follow the standard maintenance schedule under BS 5306-3:2017: monthly visual checks by the on-site responsible person, annual basic service by a competent person (BAFE SP101 registration is one way to check third-party certification), and an extended service every 5 years.
The PFAS situation adds two extra considerations at service time. First, the engineer should be able to identify and document the foam chemistry. Second, any foam extinguisher containing PFOA found during servicing must be removed from service immediately and routed to compliant disposal — a unit found to contain PFOA cannot be returned to service even if the rest of it is in good condition. The full picture is on our fire extinguisher servicing and inspection page.
How to use a foam extinguisher
The PASS technique applies, with one foam-specific note: aim to build a continuous foam blanket on a flammable-liquid surface, sweeping gently rather than blasting directly at the fuel. A direct blast at a liquid surface can splash burning fuel; a gentle sweep lays the blanket over the top.
For Class A fires, foam can be used much like water — at the base of the fire, sweeping across the burning material. Expect a wet, foam-coated mess afterwards; foam clings to surfaces longer than water and the residue requires cleaning up.
The full step-by-step is on our PASS technique guide.
Frequently asked questions
Is my foam extinguisher banned?
Not every foam extinguisher is prohibited. Check its composition against the applicable POPs limits and other restrictions. The exemption for specified PFOA foam uses ended on 4 July 2025, with use prohibited from 5 July.
Does the July 2025 ban affect every foam extinguisher?
No. The PFOA restriction is distinct from a blanket ban on every foam. PFOS and other regulated POPs also matter, and “C6” does not establish compliance. Wider Great Britain PFAS restrictions remain a separate process.
What’s the difference between C6 and C8?
C6 and C8 describe aspects of fluorinated chemistry. Both sit within the broader PFAS issue; neither label alone tells you whether a product meets current legal limits. Check manufacturer evidence for the actual formulation.
Can I refill an old AFFF extinguisher with fluorine-free foam?
Not by simply exchanging the liquid. A competent supplier must address residual contamination, approved formulations and continued fire-rating validity. Arrange replacement where compliant reuse cannot be demonstrated.
What is fluorine-free foam?
Fluorine-free foams use alternatives to fluorinated surfactants. Check the manufacturer’s formulation information and the tested fire rating; they are not automatically interchangeable with every AFFF product.
Can foam be used on electrical fires?
Only if the specific unit carries a current dielectric rating, with stated voltage and distance limits. Standard foam without that marking should not be used on live electrical equipment.
When will C6 foam be banned in the UK?
HSE’s consultation on a wider Great Britain PFAS foam restriction closed on 18 February 2026. The proposal is not itself law. Check the final regulatory decision and relevant transition provisions rather than treating an anticipated date as a current ban.
Where this connects
If you are deciding what extinguisher mix your premises needs, the hub guide on fire extinguisher types gives the full picture across all five types. For the related use cases, see the right extinguisher for flammable liquids and the right extinguisher for electrical fires. The compliance and servicing context is on fire extinguisher servicing and inspection and fire extinguisher disposal.
For the basics of fire safety in a UK workplace — what to do, who is responsible, and how to train staff — start with our online fire safety awareness training course, which is RoSPA-approved and CPD-accredited.
Related guides
- Who Is Responsible for Fire Extinguishers in the UK?
- Fire Extinguisher Disposal: The UK Guide
- Fire Extinguisher Servicing and Inspection: The UK Guide
Sources & references
Official guidance and standards checked on 15 October 2026.
- Environment Agency — POPs rules and PFOA foam exemption
- HSE — Great Britain PFAS foam restriction consultation
- Government — extinguisher selection and fire risks
- BAFE — maintenance intervals
- BS 5306-8:2023
- BAFE SP101
- BS 5306-3:2017